Overload Heater Chart

Overload Heater Chart - Web the table below should be used to determine which column of motor full load amperes applies for heater selection. Nema melting alloy overload relay selection tables. Refer to approximate thermal unit selection based on horsepower and voltage. The documentation available online is generally the latest version. If motor amps are not known, an approximate value. This applies to bimetallic overload relays with the trip adjustment set at 100 percent. A class 10 overload relay will trip in 10 seconds or less at a current equal to 600 percent of its rating. English deutsch français español português italiano român nederlands latina dansk svenska norsk magyar bahasa indonesia türkçe suomi latvian lithuanian česk. If motor amps are not known, an approximate value. The size 1 and 2 olr’s have a maximum current rating of 26.2 and 45.0 amperes respectively.

Overload Heater Sizing Chart
Overload Heater Chart Square D
Overload Relay Heater Tables
Square D Overload Chart
Square D Thermal Overload Chart A Visual Reference of Charts Chart
Overload Heater Size Chart
Overload Heater Chart Cutler Hammer Online Shopping
Overload Heater Size Chart
Figure 515. Typical heater selection table for thermal overload device
Cutler Hammer Overload Heater Sizing Chart

Joslyn Clark Overload Heater Table.

Web the type a thermal overload relay (olr) is a bimetallic device which, with the properly selected wire and heaters, will provide motor protection for running and stalled rotor overloads in motor circuits not exceeding 600 volts. Refer to the specified table and use the controller size and motor amps to select the heater catalog number. If motor amps are not known, an approximate value. Web the table below should be used to determine which column of motor full load amperes applies for heater selection.

A Class 10 Overload Relay Will Trip In 10 Seconds Or Less At A Current Equal To 600 Percent Of Its Rating.

Refer to approximate thermal unit selection based on horsepower and voltage. Web heater table number is found in the column under the type of overload and phase. The heater application table indicates the range of full load motor current to which a given heater many be applied. If motor full load current (flc) is not known, a tentative thermal unit selection could be made, based on horsepower and voltage.

Web Overload Relay By A Class Number Indicating The Maximum Time In Seconds At Which It Will Trip When Carrying A Current Equal To 600 Percent Of Its Current Rating.

Below is a list of tables of overload heaters for the more common applications. Replacement melting alloy overload relays for class 8536 starters Nema control siemens industrial control products heater tables and replacement parts 17 size heater. Separate mounting—melting alloy overload relays ;

The Size 1 And 2 Olr’s Have A Maximum Current Rating Of 26.2 And 45.0 Amperes Respectively.

Class 9065 catalog for overload relays and thermal unit selection. Web heater table number is found in the column under the type of overload and phase. The size 3 and 4 olr’s have a maximum current rating of 90 and 133 amperes respectively. Nema melting alloy overload relay selection tables.